STC Rating: How Well a Wall Stops Sound Passing Through
STC (Sound Transmission Class) is a single-number rating of how well a wall, door or glazing stops airborne sound passing from one room to the next. A higher number means better insulation. The international equivalent is Rw. Both are measured in a laboratory, so they describe the element, not the finished room.
By Dhruv Agarwal · · 1 min read
Why it matters on a project
"We can hear the next meeting room" is one of the most common complaints in a new office. It is rarely because the wrong partition was bought. It is usually because the rated partition was installed in a way that let sound go around it.
The ratings at a glance
| Rating | Measures | Measured where | Standard |
|---|---|---|---|
| STC | Sound blocked by an element | Laboratory | ASTM E90, rated under ASTM E413 |
| Rw | Sound blocked by an element | Laboratory | Rated under ISO 717-1 |
| Site (field) rating | Sound blocked between two real rooms | On site | e.g. ISO 16283-1 |
| NRC | Sound absorbed by a surface | Laboratory | Separate rating |
What protects the rating on site
- Partitions taken to the slab, or a ceiling-void barrier above them, so sound cannot travel over the top.
- Sealed perimeter at head, base and abutments.
- Sealed services penetrations, with sockets offset rather than back to back.
- Doors with perimeter and drop seals, because the door is usually the weakest element.
- Glazed partitions with suitable glass and frames, since a single sheet in a light frame often limits the wall.
- No continuous duct or open grille linking two rooms without attenuation.
Common mistakes
- Specifying a lab rating and expecting it on site.
- Stopping partitions at the false ceiling to save cost or time.
- Adding acoustic panels to fix privacy, which treats absorption, not insulation.
- A heavy wall with a standard door, where the door sets the real performance.
- Cutting the partition for cable trays late and not resealing.
Standards referenced
Laboratory measurement under ASTM E90 and rating under ASTM E413; international rating under ISO 717-1; field measurement under ISO 16283-1. Target ratings and constructions for a specific project must be set by the project's acoustic consultant.
Standards referenced
- ASTM E90 — Laboratory measurement of airborne sound transmission loss of building partitions and elements (ASTM International)
- ASTM E413 — Classification for rating sound insulation (ASTM International)
- ISO 717-1 — Rating of sound insulation in buildings — airborne sound insulation (ISO)
- ISO 16283-1 — Field measurement of sound insulation — airborne sound insulation (ISO)
Frequently asked
Related
- NRC Rating: How Much Sound a Surface Absorbs
- Acoustic Flanking: Why a Good Wall Still Leaks Sound
- Reverberation Time: Why a Room Sounds Harsh or Comfortable
- Glass vs Drywall Partitions: Daylight, Acoustics and Reconfiguration
- Demountable Partitions: Walls You Can Move
- Plenum Depth: The Ceiling Void Everything Competes For