Glass Partitions & Doors for Offices
By Dhruv Agarwal · · 2 min read
What we deliver
Glazed office partitions, frameless doors and acoustic glazed rooms — specified around the privacy each room actually needs rather than a single default applied across the floor.
Glass is what makes a modern office feel open while still being divided. It is also where acoustic expectations quietly break: clients specify glass for daylight and openness, then expect the confidentiality of a solid wall.
Scope of works
| Stage | What we deliver |
|---|---|
| Requirement | Which rooms need visual separation, which need confidentiality |
| Specification | Single or double glazed, glass thickness, acoustic target |
| Detailing | Head, base and jamb junctions; plenum sealing above |
| Hardware | Patch fittings, floor springs, locks, closers |
| Fabrication | Cut-outs formed before toughening |
| Installation | Setting out, alignment, glazing, sealing |
| Finishing | Manifestation, film or frit, handover |
Specification by room type
| Room | Typical specification |
|---|---|
| Open-plan screen | Single glazed, frameless or slim framed |
| Standard meeting room | Single or double glazed, partition to slab |
| MD cabin / HR / board room | Double glazed, offset thicknesses, sealed plenum |
| Reception / feature | Frameless, low-iron glass, patch-fitted doors |
| Focus / phone booth | Double glazed with full acoustic sealing |
Where projects go wrong
- Glass specified for openness, judged on privacy. Decide per room what it actually has to do before choosing the build-up.
- Perimeter sealing ignored. Sound over the head track through the shared plenum defeats even good glazing.
- Hardware chosen after the glass is ordered. Cut-outs are made before toughening; a late change means new glass.
- Manifestation forgotten. Full-height clear glass in a circulation route is a walk-into hazard and needs visible marking.
- Floor spring pocket formed badly. The most common cause of frameless doors that sag, bind or stop closing.
Why Hagerstone
Glass expertise across the business. The same organisation delivers facade glazing, structural silicone and frameless entrance doors, so interior glazing is detailed by people who work with glass at building scale — not treated as a joinery afterthought.
In-house fabrication with CNC-grade machinery, under ISO 9001 / 14001 / 45001 and 79+ quality checkpoints.
Standards referenced
Architectural safety glass, including where toughened or laminated is required, under IS 2553 (Part 1). Means of egress and door requirements under NBC 2016, Part 4.
Standards referenced
- IS 2553 (Part 1) — Safety glass — architectural
- NBC 2016, Part 4 — Fire and life safety — means of egress