Office Lighting Design

By Dhruv Agarwal · · 2 min read

What we deliver

Lighting design and installation for offices — lux levels, layouts, fitting selection, controls and emergency lighting, integrated with the ceiling design rather than laid over it.

Most office lighting is not designed. Fittings get spaced evenly on a grid until the ceiling looks balanced, and the result is a floor that meets an average number while being uncomfortable to work under.

Scope of works

StageWhat we deliver
RequirementTask types per zone, target lux, ceiling type, daylight
CalculationLux and uniformity on the working plane, not the ceiling
LayoutFitting positions coordinated with the reflected ceiling plan
SelectionFitting type, optics, colour temperature, CRI
ComplianceLighting power density against ECBC 2017
ControlsDaylight linking, occupancy sensing, scene setting
EmergencyEscape route and exit sign lighting
InstallationWiring, mounting, commissioning, focusing

Typical design targets

ZoneWorking-plane luxNotes
Open plan desks300-500Uniformity matters as much as the average
Meeting rooms300-500Dimmable for presentation
Reception200-300Feature and accent lighting
Circulation150-200Lower, with emergency coverage
Cafeteria200-300Warmer colour temperature
Detailed / drawing work500-750Task lighting supplements general

Where projects go wrong

  • Designing to average lux and ignoring uniformity. Bright pools with dark gaps read as a badly lit office regardless of the average.
  • No glare control. Screen reflections and direct glare make an otherwise adequate floor unpleasant to work in.
  • Lighting drawn after the ceiling. Fittings then compete with diffusers, sprinklers and detectors for the same tile.
  • Mixed colour temperature. Fittings from different batches or suppliers on one floor are immediately visible.
  • Emergency lighting left to the end. Escape route coverage is a compliance requirement and needs to be in the layout, not added afterwards.

Why Hagerstone

Customised lighting is part of our stated scope, delivered with the ceiling and the electrical installation by one team — so the lighting plan, the reflected ceiling plan and the circuit design are the same conversation.

15 electricians in-house, ISO 9001 / 14001 / 45001, 79+ quality checkpoints.

Standards referenced

Interior illumination levels and practice under IS 3646. Lighting power density limits under ECBC 2017.

Standards referenced

  • IS 3646Code of practice for interior illumination
  • ECBC 2017Lighting power density