Curtain Wall Systems — Unitised, Semi-Unitised and Conventional

A curtain wall is a glazed building facade built in one of three configurations: unitised, with panels assembled in the factory; conventional stick, assembled piece by piece on site; or semi-unitised, which combines site-erected framing with factory-prepared infill. The choice depends on building height, panel repetition, crane access and programme.

By Dhruv Agarwal · · 2 min read

What we deliver

Curtain wall in all three configurations — unitised, semi-unitised and conventional stick — engineered, fabricated and installed as one accountable package rather than split between a designer, a fabricator and an installer.

The system choice is made on evidence at survey stage. Building height, panel repetition, crane availability and programme all point to a different answer, and the wrong choice is expensive to reverse once brackets are set.

Facade leadership experience

Our Director – Facade, Akhilesh Kumar Singh (25+ years in facade engineering), has led delivery on projects including:

ProjectLocationScopeQuantity
DLF — Building 8Cyber City, GurgaonStick curtain wall glazing, aluminium solid sheet, Galvalume & Shera board cladding14,175 sq. m.
Broadway Service ApartmentDwarka Expressway, Sector 83, GurugramCurtain wall glazing & aluminium doors and windows10,550 sq. m.
Anygraphics FactoryNoida, Uttar PradeshSemi-unitised structural glazing, PIR panel, rock wool panel6,500 sq. m.

Scope of works

StageWhat we deliver
Survey & assessmentMeasured survey, slab edge condition, system recommendation
Design & engineeringWind load analysis to IS 875 Pt 3, shop drawings, bracket design
Mock-up & testingVisual approval, ASTM E283 / E331, structural loading, water re-test
FabricationIn-house cutting, routing, crimping, end milling, in-process inspection
InstallationSetting out, bracket fixing, panel erection, sealing
Testing & handoverSite water testing, snagging, O&M documentation

What drives the cost

Height and access strategy · panel repetition across the elevation · glass specification (SHGC, U-value, DGU build-up) · framing depth set by wind pressure · whether the facade is unitised or stick · corner and setting-out complexity · programme compression.

Where projects go wrong

  • System chosen before the survey. Slab edge tolerance and crane access frequently rule out the system that was assumed at concept.
  • Ordering before the mock-up is signed off. Once production starts, a change means re-tooling.
  • Structural glazing bite copied from another project. Wind pressure is building-specific; corner and upper-floor panels need more than the average.
  • Spandrel treated as an afterthought. The cavity behind runs far hotter than the vision area and needs heat-strengthened glass and insulation behind it.

Why Hagerstone

100% in-house execution under a Director — Facade with 25+ years in facade engineering, structural glazing and high-rise exterior work, supported by a dedicated 20-member facade team.

79+ quality checkpoints, in-process inspection and sign-off before despatch, under ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 certification.

One accountable partner — facade coordinated with interiors, MEP, civil and PEB rather than split across vendors who each blame the other at the interface.

Standards referenced

Wind loading to IS 875 (Part 3). Air and water performance verified to ASTM E283 and ASTM E331. Quality management to ISO 9001:2015.

Standards referenced

Frequently asked

It depends on height, repetition and programme, not on preference. Unitised suits tall or fast-track buildings with repeating panels, because factory assembly removes facade scaffolding and compresses the site programme. Stick suits low-rise and irregular geometry where few panels repeat. Semi-unitised sits between them — primary framing erected on site, infill panels prepared in the factory. We assess this at survey stage rather than defaulting to one system.

In-house. Our facade fabrication runs in an approximately 9,000 sq ft facility with over 10,000 sqm per month capacity, on CNC-grade machinery including a fully automatic double head cutting machine with ±0.1mm servo precision, copy router, corner crimping and end milling. Execution is 100% in-house with a dedicated 20-member facade team.

Through mock-up testing before production release — air infiltration to ASTM E283, static water penetration to ASTM E331, then structural loading and a water re-test after the frame has flexed. Test pressures derive from the design wind pressure for that specific building under IS 875 Part 3, not from a default value.